Concord 4 Default Installer Code

Concord 4 User Manual 5 Basic commands Table 1 below shows the basic commands. Table 1: Basic commands Command Instructions Disarm the system Press 1, code. Cancel an accidental alarm Press code or press 1, code. Arm to Level 2 (stay) Press 2, code. If the quick arm feature is on, an access code. In this video, Jorge from Alarm Grid helps you find your Installer Code on a VISTA-21iP Alarm System. By default, this code is set to 4112. We advise keeping.

Master Codes and Installer Codes both have different functions. The Installer Code on a panel is used for entering installer programming mode. In this mode, various changes to the function of the system can be made. Meanwhile, the Master Code is used primarily for arming and disarming.


When the Installer Code is entered on a panel, the user will be taken to a different menu than if they enter their Master Code. This menu allows users to add and program new devices, change system settings, and change delay times. The Installer Code can also change the Master Code, but it cannot assign any other user codes. Additionally, the Installer Code can never be used to disarm a system, unless it was the code used to arm the system in the first place.

Concord 4 Default Installer Code

The Master Code is the primary code for the alarm system. In addition to arming and disarming the alarm system, the Master Code provides access to a user menu. From there, you can add, edit and delete user codes, change the master code, view the event log, set the system clock, program keypad macros, set scheduled events and activate output devices like triggers and relays. The Master Code can always disarm the system, even if it was not armed using that code.

In addition to Master and Installer codes, there are also User Codes. These codes can perform basic arming and disarming functions, as well as zone bypassing, and they are a good way to allow a person to reliably arm and disarm the panel, without having to provide them with the Master Code.

It should be noted that the Installer Code and the Master Code on a panel can never be the same. Each needs to have its own unique four-digit number. Every alarm system brand has a standard default Installer Code and Master Code. Knowing these codes can be helpful for accessing a panel after it has reset to factory default. Below are some of the default codes:

  • Honeywell: Master - 1234 ; Installer - 4112
  • 2GIG: Master - 1111 ; Installer - 1561
  • Qolsys: Master - 1234 ; Installer - 1111

Did you find this answer useful?

We offer alarm monitoring as low as $10 / month

Click Here to Learn More
Here is an FAQ reviewing how to delete zones: https://www.alarmgrid.com/faq/how-do-you-delete-a-honeywell-wireless-device
How can i disable zone on a vista 128?
Thanks Julia! I have being reading through your FAQs here at AG and am learning so much about the system that we bought--much appreciated!
No, reporting of program entry/exit is not a programmable option on that panel. It will not report it.
Well mine is an L7000--is there an option somewhere that I can check to see if it is enabled or disabled?
Entry to, and exit from, programming are not reported on most residential burglary panels. If there were an option to report it, we would not enable it.
I'm wondering about what uses of the Installer code get sent to AlarmNet and the Central Station? It seems clearly that if the Installer code is used to arm or disarm that would get sent, but does its use to enter Programming Mode also get sent to AlarmNet and then to CS? If yes, what use might either or both make of that record?
Great.....Thanks for the info
No, accessing the panel's programming using the 'backdoor' method will not wipe out the existing panel programming.
On a Vista 20P if I reset the panel using the power up option to change the Installer code, does that erase the zones that are currently programmed into the panel? I don't know the current code.

Related Products

LYNX Touch Wireless Security System with 4-1/3 inch Screen
Code
Our Price:$221.99
LYNX Touch Wireless Home Security System and Alarm Control Panel
Wireless Home Security System w/ 7-inch Screen
Our Price:$314.99
DIY Wireless Security System w/ 7-inch Screen
Go!Control Wireless Security System

Related Categories

Answered

One of the more frustrating things for me is when someone, or some company, attempts to control me. Typically having the desire for less responsibility, I have no desire to control individuals in this way. Recently, I started looking into what moving my alarm system to a new monitoring service would entail. The primary goal included eliminating the dependence on a landline and getting the flexibility to do reconfigurations myself. I own the alarm system and I felt like I should be able to make those changes.

Upon investigation, I found that my alarm system was a bit challenging to reset the installer code. Searching the Internet yielded several options to try–1234, 9876, 4112 and 6112. Unfortunately, none of those worked for my system and a call to my current alarm service company was met with, “We don’t provide those, we want to protect you from

making accidental changes.” They eventually agreed to try to change the code to another value and called me back a few times. Eventually, their remote effort fizzled out, but I’m

sure they would’ve changed them with an on-site visit and a $75 service fee.

A few searches on the internet suggested copying EEPROMs or analyzing them. I fo

und that my unit used a MIC24LC64 chip and started researching ways to read it.

Disclaimer: Use this process at your own list. It worked for me, but I practiced the process on a separate alarm panel that had no value. Removal of and reading of the EEPROM may result in a damaged chip or loss of configuration if it is not done properly.

For me, the biggest challenge was getting an EEPROM reader working with my computer. The EEPROM reader that I purchased is a “SMAKN® USB Port 24CXX EEPROM Programmer Reader Writer to 24C1024 for XP VISTA WIN7” that I picked up from Amazon for roughly $10. It is cheap and also lacking documentation and software. Getting the software working and reading an EEPROM was a bit of a challenge. My first recommendation is watching this video from YouTube.

YouTube — USB EEPROM Programmer and CH341A **DOWNLOAD LINKS

As I was looking for the software for this reader I was inundated with links to questionable sites. So it might make sense to do this a computer that doesn’t have personal information and can be easily wiped. After following the YouTube video above, I was able to get the application to work in English and show “Connected”. Even at that point, I was unable to get it to properly read the EEPROM and all the registered showed FF.

Adt Default Installer Code

Chip Orientation Matters

In the video, Kris calls into question the orientation of the chip. Typically, the handle on a ZIF socket is used to locate PIN 1. There is also often a square footprint on the solder joint at PIN 1. This aligned with what Kris mentioned in the video but did not seem to work wit my MIC24LC64. Additionally, the positioning in the application did not work either. I actually believed that my reader might be bad.

Honeywell Default Installer Code

Ultimately, I tried both possible positions on the other end of the socket. With PIN 1 in the middle, the chip was instantly VERY hot (and I assumed I had ruined it). After I turned it around, placing my chip’s PIN 1 (note the notch in one end of the chip–the end with pin 1) in the socket’s PIN 16, I was able to read data it with the CH341 application.

Not knowing what to look for, I had preprogrammed a series of numbers as the installer code on a test unit. I was unsure whether the manufacturer used an ASCII translation or some other method of encoding the number sequence. What I found was that the sequence existed at ‘000001900E-0F’ and was visible in the HEX section of the software. In other words, each number was encoded into a sequencial 4-bit nibble. To test my theory, I reinstalled the EEPROM into the surrogate system and changed it. Sure enough, the change was represented properly when I re-read the output.

Below is a graphic showing a default installer code (4321) and a default master code (1234).

Dsc Default Installer Code

Reading My Main Alarm’s Installer Code

At this point, I decided to pop the chip from my home alarm system and read it. A numeric sequence also appeared at the same location. I reinserted the chip into the panel and powered it back up. Testing the installer code by entering ‘8 – CODE – 00’ revealed that I could now access the System Programming Menu.

Concord 4 Default Installer Codes

Conclusion

I spent far more time reverse engineering my alarm system than the value if I’d paid the company to come out and reset it to a code they could provide to me. However, there is a great satisfaction for me when I learn something from the task at hand. I do think it is also worth mentioning that this code can be used to arm and disarm a system. Operating under the assumption that many alarm companies use a common installer code across all customers, this code may be known by all of the technicians. That’s a bit scary IMO.

Disclaimer: This article includes the independent thoughts, opinions, commentary or technical detail of Paul Stewart. This may or may does not reflect the position of past, present or future employers.